Wednesday, May 15, 2024     
     Serving the Electronic Industries for Over 33 Years
Amp connectors sockets Logo
Frontline Switches products page
Ditek Surge Protection logo
Sycom Surge Suppression Devices& UPS
     Electronic Components Distributor Logo                        
 Home
  |  View Account   |    Engineer's Corner    |  Contact Us  |  Cross Reference  |  Line Card  |  0 Item
Part Search
NTE Cross Ref. Search
Login
SRI Live Chat Help
call us email us contact us

Product Links

Inside SRI

About SRI
Contact Us
Careers
Link to Us!
Feedback

SRI-Newsletter
Subscribe to our newsletter to receive monthly specials, manufacturer's feature, and electronics news via email.

See Our latest release of SRI-Newsletter here

View Our List of Archived Newsletter Articles


SRI Links

Visit our Sister Site,

Distributor of

Industrial Products

  Web Search ..
  Powered by;

 Thermal Circuit Breakers, R59 Series

R59 Series
Thermal Circuit Breaker, Fuse Holder Type

 Features
  • Replaces slow blow glass cartridge fuse
  • .250" (6.35mm) Quick Connect terminals
  • Snap-in mounting
  • Visual trip indicator
  • Push button to reset breaker
  • Electrical Characteristics Electrical Characteristics (@ 25°C)
    Calibration: Will continuously carry 100% of rating. 0.25 to 2 Amp types: May trip between 101% and 174%, but must trip at 175% of rating within one hour at +25°C. 3.0 to 20 Amp types: May trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C.
    Maximum Operating Voltages: 32 VDC; 250 VAC, @ 50/60 Hz
    Dielectric Strength: 1500VAC RMS
    Resettable Overload Capacity:
    0.25 to 2 Amp types: Six times rated current
    3.0 to 20 Amp types: Ten times rated current
    Reset Time: 0.25 to 2 Amp types: 180 seconds max.
    3.0 to 20 Amp types: 10 to 60 seconds typ.
    Interrupt Capacity: 1000 Amps @ 250VAC, 50/60Hz and 32 VDC in accordance with UL standard 1077

    Mechanical Characteristics
    Termination .250" (6.35mm) Quick Connect Terminals
    NOTE: Soldering to terminals is not recommended.
    Mounting: Snaps into panel from front
    (See recommended Panel Cutouts)
    Weight: 0.35ozs. (10g) approx.

    Back to Top

    Dimensional Drawings
    D41 


    Cutout 

    Back to Top

    Part Numbers
    DC OPERATED
    NTE Type No. Current Rating
    (Amps)
    Typical Resistance
    (Ohms)
    R59-0.25A
    0.25
    14.0
    R59-0.5A
    0.50
    3.55
    R59-1A
    1.0
    0.89
    R59-2A
    2.0
    0.17
    R59-3A
    3.0
    0.069
    R59-4A
    4.0
    0.043
    R59-5A
    5.0
    0.030
    R59-6A
    6.0
    0.026
    R59-7A
    7.0
    0.017
    R59-8A
    8.0
    0.016
    R59-10A
    10.0
    0.011
    R59-12A
    12.0
    0.009
    R59-15A
    15.0
    0.007
    R59-20A
    20.0
    0.007

    Trip Times
    0.25 to 2 Amp Types
    3 to 20 Amp Types
    Rated
    Load
    Trip Times
    Rated
    Load
    Trip Times
    100%
    No Trip
    100%
    No Trip
    175%
    Trip in 1 Hr.
    135%
    Trip in 1 Hr.
    200%
    4.5 to 28 Sec.
    200%
    2.2 to 15 Sec.
    400%
    1.0 to 6.5 Sec.
    400%
    0.55 to 1.8 Sec.
    600%
    0.4 to 4.0 Sec.
    600%
    0.27 to 0.7 Sec.
    -
    -
    800%
    0.17 to 0.45 Sec.
    -
    -
    1000%
    0.12 to 0.3 Sec.